Century S244 Especificaciones

Busca en linea o descarga Especificaciones para Estufas Century S244. Century S244 Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 47
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
READ AND KEEP THIS MANUAL FOR REFERENCE
45398A
CENTURY E.P.A. WOOD STOVE MANUAL
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOOD STOVE
Verified and tested following
ULC S627 and UL 1482 Standards
by:
STOVE BUILDER INTERNATIONAL INC..
1700, Leon-Harmel, Quebec City (Quebec), Canada G1N 4R9
Tel : (418) 527-3060
Fax : (418) 527-4311
Vista de pagina 0
1 2 3 4 5 6 ... 46 47

Indice de contenidos

Pagina 1

READ AND KEEP THIS MANUAL FOR REFERENCE 45398A CENTURY E.P.A. WOOD STOVE MANUAL US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED

Pagina 2

9 Graphic 5 A- 25 mm (1 po.) minimum; 1- Combustible wall; 2- Non-combustible spacer; 3- Brick. Graphic 6 A- 25 mm (1 po.) minimum; 1- Comb

Pagina 3 - TABLE OF CONTENTS

10 1.4 FLOOR PROTECTOR If the stove is to be installed on top of a combustible floor, it must be guarded by a non-combustible material extending at

Pagina 4

11 SECTION 2.0 CHIMNEY (FLUE SYSTEM) 2.1 DEFINITIONS For clarity, the following definitions should be used with respect to these instructions: • A

Pagina 5 - SECTION 1.0 INSTALLATION

12according to the manufacturer's specifications. The manufacturers’ installation instructions and specified clearances should always be followe

Pagina 6 - For mobile home installation

13insure that it is not obstructed, thus blocking the draft. It should be cleaned when necessary. FIGURE 2.2 Minimum Height of the Chimney 2.2.1

Pagina 7 - Shielding

14Stove pipe • An adequate number of stove pipe sections. • A 90o elbow Typical installation through the wall FIGURE 2.2.1 (A) Typical ins

Pagina 8 - Graphic 1

151- Start by positioning your stove where you would like it to go, taking into account the minimum clearances to combustible material. You will th

Pagina 9 - Graphic 2

164- Then, from outside the building, slide a short chimney length (attached to the tee) through the wall thimble. The chimney must extend at least

Pagina 10

17 6- You can start to add chimney sections. We recommend that you also use locking bands to secure all connections. You will need to secure the ch

Pagina 11 - FIGURE 1.4 Floor protector

189- You are now ready to connect your chimney to your stove. Simply install the inter-connecting stove pipe between the stove pipe adapter and the

Pagina 12 - 2.2 CHIMNEY

1INTRODUCTION Stove Builder International, one of the most important wood stove and fireplace manufacturers in North America, congratulates you on y

Pagina 13

19 Typical installation through the ceiling FIGURE 2.2.1 (B) Typical Installation Through the Ceiling

Pagina 14

20 1. Place your stove where you would like it located and use a plumb line to mark the ceiling directly above your stove flue. You will probably

Pagina 15

21 4. Once the support is secure, you can begin to assemble the chimney by lowering the first section into the support. Make sure that the male cou

Pagina 16

22 7. Once you have cut through your roof and framed the joists, it is time to work outdoors. Authorities require that the chimney extend not less

Pagina 17

239. You are now ready to connect your chimney to your stove. Simply install the inter-connecting stove pipe between the stove pipe adapter and the

Pagina 18

242.2.2 Typical installation through an existing masonry chimney You can also install your stove using your existing masonry chimney. To do so, fol

Pagina 19

25 FIGURE 2.2.2 (B) Factory Built Thimble

Pagina 20

26 FIGURE 2.2.2 (C) Brick Thimble

Pagina 21

272.3 CHIMNEY CONNECTOR Your chimney connector (commonly called stove pipe) and chimney must have the same diameter as the stove’s exhaust outlet. T

Pagina 22

28 FIGURE 2.3 (B) Minimum Slope Avoid 90 degree eblows We recommend that you use two 45 degree elbows instead

Pagina 23

2TABLE OF CONTENTS SECTION 1.0 INSTALLATION ... 4 1.1 G

Pagina 24

29 2.4 DRAFT Your E.P.A Century stove’s performance will be optimised if it is installed with a chimney (flue) system that provides an adequate dra

Pagina 25

30In order to prepare your stove for the connection to a fresh air kit, please follow the following steps. (only available with FW2470 model) 1-

Pagina 26

312.6 THE ADVANTAGE OF INSTALLING A BLOWER (FAN) A blower can be installed at the back of your E.P.A Century stove. This option is necessary if you

Pagina 27

32SECTION 3.0 OPERATION Keep these instructions for future reference. WARNING: • ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN

Pagina 28 - 2.3 CHIMNEY CONNECTOR

33 • Do not abuse the unit, either by over firing or by using wood or combustibles with salt content, or harmful chemicals. Misuse is not covered b

Pagina 29

343.2 FUEL Fuel for the stove must not be stored closer than the required clearances to combustibles (heat sensitive materials). NEVER STORE WOOD IN

Pagina 30 - 2.5 OUTSIDE COMBUSTION AIR

353.2.1 The use of manufactured logs There are numerous types of manufactured logs sold on the market. You must be very careful with this type of

Pagina 31

363.4 LIGHTING A FIRE • Place enough crumpled balls of newspaper or other paper into the stove to cover the bottom of the firebox. • Place small

Pagina 32

37 Increase air Decrease air Air control adjustment for model FW2470 3.5 MAINTAINING THE FIRE Once the wood has been consumed (or

Pagina 33 - SECTION 3.0 OPERATION

38For the FW700 and the FW3000 model, we suggest that you operate it with the air control slightly open (approximately 10%) to achieve an optimum eff

Pagina 34

3SECTION 5.0 FEATURES ... 42 5.1 S244 ...

Pagina 35 - 3.2 FUEL

39 SECTION 4.0 MAINTENANCE 4.1 CLEANING AND PAINTING YOUR STOVE Clean the stove frequently so that soot, ash, and creosote do not accumulate. Do n

Pagina 36 - 3.3 NOTES ABOUT FIRST FIRING

404.3 GASKETING It is recommended that you change the door gasket (which makes your stove door air tight) once a year, in order to insure good contr

Pagina 37 - 3.4 LIGHTING A FIRE

41 • If bright embers are glowing above the ash dump cap during a low or medium fire, air may be leaking past the ash plug. If this is happening, a

Pagina 38

42SECTION 5.0 FEATURES 5.1 S244 Type of fuel Wood Test standard ULC S627 (CSA B366.2) and UL 1482 for residential. Recommended surface

Pagina 39 - 3.6 FAN (BLOWER) OPERATION

43 5.2 FW2470 Type of fuel Wood Test standard ULC S627 (CSA B366.2) and UL 1482 for residential. Recommended surface : 500 to 1300 sq.ft

Pagina 40 - SECTION 4.0 MAINTENANCE

445.3 FW2700 Type of fuel Wood Test standard ULC S627 (CSA B366.2) and UL 1482 for residential. Recommended surface : 700 to 1700 sq. ft

Pagina 41 - 4.3 GASKETING

455.4 FW3000 Type of fuel Wood Test standard ULC S627 (CSA B366.2) and UL 1482 for residential. Recommended surface : 800 to 2000 sq. f

Pagina 42 - 4.5 CHIMNEY (FLUE) CLEANING

46CENTURY HEATING LIMITED WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This war

Pagina 43 - SECTION 5.0 FEATURES

4SECTION 1.0 INSTALLATION When installed and operated as described in these instructions, the E.P.A Century wood stove is suitable for use as a fre

Pagina 44 - 5.2 FW2470

51.3 CLEARANCES Clearances to any combustibles when measured directly from the floor protector to the ceiling must be a minimum of 84" (2134 m

Pagina 45 - 5.3 FW2700

6 1.3.1 Reduced clearances You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. Th

Pagina 46 - 5.4 FW3000

7 Graphic 1 A- Clearance to combustible material with no protection. B- 500 mm (20 po.) minimum; C- 25 mm (1 po.) minimum; D- Between 25 mm

Pagina 47 - DESCRIPTION

8 Graphic 2 A- 25 mm (1 po.) minimum; 1- Combustible wall ; 2- Non-combustible spacer; 3- 0.61 mm (0.024") sheet metal. Graphic 3 A- 25 mm

Comentarios a estos manuales

Sin comentarios